使用
通過式清洗機(jī)時,正確的預(yù)清洗和設(shè)備放置對有效清洗會很重要。下面小編就來為您講講相關(guān)事項(xiàng)的操作。
When using a pass through washer, proper pre cleaning and equipment placement are important for effective cleaning. The following section will tell you about the operation of related matters.
對于手動清潔,應(yīng)遵循以下步驟:
For manual cleaning, the following steps should be followed:
(1)清潔前,松開螺釘和螺母,或根據(jù)制造商的說明拆卸設(shè)備。
(1) Before cleaning, loosen the screws and nuts or disassemble the equipment according to the manufacturer's instructions.
(2)應(yīng)使用冷水清洗被污染的儀器,以去除污染物并防止蛋白質(zhì)在儀器上凝固。
(2) Contaminated instruments should be washed with cold water to remove contaminants and prevent protein from solidifying on the instrument.
(3)用手清潔時,請仔細(xì)遵循制造商的說明。所有內(nèi)腔都應(yīng)該仔細(xì)刷和清洗。清洗不當(dāng)?shù)膬x器會影響氣蝕過程。
(3) When cleaning by hand, carefully follow the manufacturer's instructions. All internal cavities should be carefully brushed and cleaned. Improperly cleaned instruments will affect the cavitation process.
(4)沖洗并檢查儀器表面是否有殘留污染物。
(4) Rinse and check the instrument surface for residual contaminants.
通過式清洗機(jī)裝載已清洗的儀器時,應(yīng)遵循以下步驟:
The following steps should be followed when loading the cleaned instrument with the through type cleaner:
(1)將手動清潔的儀器放入批準(zhǔn)的金屬網(wǎng)盤中。分離不同的金屬(某些金屬的混合會導(dǎo)致離子轉(zhuǎn)移,導(dǎo)致點(diǎn)蝕和表面蝕刻)。
(1) Place the manually cleaned instrument in an approved metal mesh tray. Separate different metals (the mixing of some metals will cause ion transfer, leading to pitting and surface etching).
(2)將鉸接儀器置于全開狀態(tài)。
(2) Place the articulated instrument in the fully open position.
(3)應(yīng)準(zhǔn)備套管/內(nèi)腔儀器(完全充滿溶液),并將其放置在水平位置。
(3) The casing/lumen instrument shall be prepared (completely filled with solution) and placed in a horizontal position.
(4)避免將儀器擁擠在網(wǎng)格托盤中(溶液循環(huán)需要足夠的空間)。圖1顯示托盤中的儀器太擁擠,無法進(jìn)行適當(dāng)?shù)娜芤呵逑础?/div>
(4) Avoid crowding the instrument in a grid tray (adequate space is required for solution circulation). Figure 1 shows that the instruments in the tray are too crowded for proper solution cleaning.
(5)將裝入的儀器托盤放入超聲波清洗機(jī)中。注意:托盤不應(yīng)堆疊。
(5) Put the loaded instrument tray into the ultrasonic cleaner. Note: Pallets should not be stacked.
(6)根據(jù)制造商的說明檢查儀器的正確周期時間。
(6) Check the correct cycle time of the instrument according to the manufacturer's instructions.
(7)沖洗并檢查儀器。
(7) Flush and check the instrument.
讓大家更加熟悉這個產(chǎn)品,發(fā)揮很大的作用,以上就是關(guān)于問題的講解內(nèi)容了,希望幫助到您,有什么問題或者需求歡迎來我們網(wǎng)站
www.zjfsmy.com進(jìn)行咨詢!
Let everyone be more familiar with this product and play a great role. The above is the explanation of the problem. I hope to help you. If you have any questions or needs, please come to our website www.zjfsmy.com for consultation!